Novel point-of-care technology delivers accurate HIV results in minutes


A team of Northwestern University scientists spanning disciplines have developed new technology that could lead to the creation of a rapid point-of-care test for HIV infection competitive with traditional lab-based HIV testing in a fraction of the time and without the need for a stressful wait while results are processed or confirmed in a clinical laboratory.
HIV-diagnostic technology traditionally relied on the detection of HIV-specific antibodies that form several weeks after infection. This has limited their use in early detection, complicating patient care and HIV prevention efforts. Newer tests that detect both HIV antibodies and the p24 antigen (an earlier marker of HIV infection) are now the gold standard for diagnosis, but require clinical labs to run results, contributing to longer processing times, higher costs and the need for multiple patient visits.
The technology described in a study published in the journal Biosensors and Bioelectronics uses a nanomechanical platform and tiny cantilevers to detect multiple HIV antigens at high sensitivity in a matter of minutes.
These silicon cantilevers are cheap and easy to mass produce and can be readily equipped with a digital readout. Built into a solar-powered device, this technology could be taken to hard-to-reach parts of the world where early detection remains a challenge to deliver fast interventions to vulnerable populations without waiting for a lab.
“We hope this technology will lead to the development of new point-of-care diagnostics for HIV to improve patient health and help bring an end to this epidemic,” said Northwestern virologist and co-author of the study, Judd F. Hultquist.
After proving its efficacy in testing for both the SARS-CoV-2 virus that causes COVID-19, and now HIV, the team is confident that the biosensor will continue to prove effective when testing for additional diseases. A potential next target, they say, could be measles, another infection in desperate need of point-of-care interventions as cases rise across multiple U.S. states.
The team was led by co-corresponding authors Vinayak Dravid, a materials engineer, Hultquist, a virologist, and co-author Gajendra Shekhawat, a micro- and nanofabrication expert in the Dravid Lab.
“When we first developed the microcantilever technology 20 years ago, I realized that this technology is so generally applicable,” Dravid said. “It is a very powerful tool that depends on three basic things: sensitivity, antigen-antibody affinity and specificity. This is where HIV comes in, because HIV is so pernicious that it mutates so there is no unique antibody. We had to figure out how to overcome that challenge.”
Beginning with pure samples of the p24 antigen, the team applied layers of antibodies onto each “finger” of the gold-coated microcantilever to measure how strongly p24 bonded to the surface, which would cause the cantilever to bend a measurable and quantifiable amount.
After this proof-of-concept, the team introduced human blood samples, which are much more complex than purified samples. The sensor continued to bend only in samples where p24 was present, demonstrating high specificity.
Finally, the scientists added two antibodies to different “fingers” of the microcantilever to more broadly cover all HIV subtypes. Even in very low concentrations, the test accurately responded when antigens specific to HIV were introduced.
“To account for HIV’s genetic diversity, we functionalized the test for HIV using broadly cross-reactive antibodies (ANT-152 and C65690M),” Shekhawat said. “This allowed accurate detection across diverse HIV-1 subtypes, ensuring reliability in global settings.”
To streamline diagnostics and enable immediate medical care, the team envisions developing a point-of-care test to simultaneously detect HIV, hepatitis B and hepatitis C antigens, acknowledging the higher prevalence of hepatitis co-infections in people living with HIV, which can lead to severe liver complications if left untreated.
More information:
Angel Green Samuel et al, Nanomechanical Systems for the rapid detection of HIV-1 p24 antigen, Biosensors and Bioelectronics (2025). DOI: 10.1016/j.bios.2025.117395
Citation:
Novel point-of-care technology delivers accurate HIV results in minutes (2025, April 2)
retrieved 2 April 2025
from https://medicalxpress.com/news/2025-04-technology-accurate-hiv-results-minutes.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no
part may be reproduced without the written permission. The content is provided for information purposes only.
If you liked the article, do not forget to share it with your friends. Follow us on Google News too, click on the star and choose us from your favorites.
If you want to read more Like this articles, you can visit our Science category.